12
Installation and Operation
NSD Safety Mat System
NSD-DR-04 (DIN-rail Controller with Diagnostics)
Jumper Settings
1= jumper install
Number of Mats:
JP2 JP1
0 0 1 mat
1 0 2 mats
0 1 3 mats
1 1 4 mats
JP3
1= Manual relay reseting
0= Automatic relay reseting
JP4
1= External relay checking enabled
0= Disabled
JP5
Not used at this time
JP6
Not used at this time
NSD-DR-04 (DIN-rail Controller with diagnostics)
Board Connector Layout
J2,J26 MAT INPUT #1 thru #4 JP1,2 NUMBER OF MATS SELECTION
J1 DIAGNOSTICS DISPLAY (remote) JP3 MANUAL
J120 POWER/OUTPUT JP4-6 EXT, AUX1, AUX2
D13,14 Safety relay output on (closed) D3 +12v supply
D16 Auxiliary relay output on D1 +5v supply
D15 Fault relay output on (closed) D23 +20v supply